首页 / 产品 / ELISA试剂盒 / 人ELISA试剂盒
产品描述:人骨桥素(OPN)酶联免疫试剂盒为双抗夹心法ELISA试剂盒,定量检测血清、血浆、尿液、组织匀浆样本中的OPN含量。试剂盒检测范围为0.78 ng/mL-50 ng/mL,灵敏度为0.195 ng/mL。该产品可应用于基础研究中对OPN表达水平的动态监测,如骨代谢异常机制探究、肿瘤微环境分析、慢性炎症模型构建等领域,尤其适用于细胞实验、动物模型或人体生物样本中OPN蛋白浓度的对比研究,为探索其生理病理功能提供可靠工具。本品仅用于科研,不用于临床诊断,产品具体参数及操作步骤详见产品说明书。
别名:BNSP ELISA Kit; Bone sialoprotein 1 ELISA Kit; Bone sialoprotein I ELISA Kit; BSP I ELISA Kit; BSPI ELISA Kit; Early T lymphocyte activation 1 ELISA Kit; ETA 1 ELISA Kit; ETA1 ELISA Kit; MGC110940 ELISA Kit; Nephropontin ELISA Kit; OPN ELISA Kit; Osteopontin ELISA Kit; osteopontin/immunoglobulin alpha 1 heavy chain constant region fusion protein ELISA Kit; OSTP_HUMAN ELISA Kit; PSEC0156 ELISA Kit; secreted phosphoprotein 1 (osteopontin bone sialoprotein I early T lymphocyte activation 1) ELISA Kit; secreted phosphoprotein 1 (osteopontin, bone sialoprotein I, early T-lymphocyte activation 1) ELISA Kit; Secreted phosphoprotein 1 ELISA Kit; SPP 1 ELISA Kit; SPP-1 ELISA Kit; SPP1 ELISA Kit; SPP1/CALPHA1 fusion ELISA Kit; Urinary stone protein ELISA Kit; Uropontin ELISA Kit
缩写:OPN
Uniprot No.:P10451
种属:Homo sapiens (Human)
样本类型:serum, plasma, urine, tissue homogenates
检测范围:0.78 ng/mL-50 ng/mL
灵敏度:0.195 ng/mL
反应时间:1-5h
样本体积:50-100ul
检测波长:450 nm
研究领域:Cancer
测定原理:quantitative
测定方法:Sandwich
精密度:
Intra-assay Precision (Precision within an assay): CV%<8% | ||||||
Three samples of known concentration were tested twenty times on one plate to assess. | ||||||
Inter-assay Precision (Precision between assays): CV%<10% | ||||||
Three samples of known concentration were tested in twenty assays to assess. | ||||||
线性度:
To assess the linearity of the assay, samples were spiked with high concentrations of human OPN in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. | ||||||
Sample | Serum(n=4) | |||||
1:5 | Average % | 94 | ||||
Range % | 88-98 | |||||
1:10 | Average % | 100 | ||||
Range % | 94-104 | |||||
1:20 | Average % | 93 | ||||
Range % | 88-97 | |||||
1:40 | Average % | 99 | ||||
Range % | 93-104 |
回收率:
The recovery of human OPN spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. | ||||||
Sample Type | Average % Recovery | Range | ||||
Serum (n=5) | 95 | 81-97 | ||||
EDTA plasma (n=4) | 102 | 97-106 | ||||
标准曲线:
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. | ||||||
ng/mlOD1OD2AverageCorrected 502.4182.3332.3762.271 251.6841.7061.6951.590 12.51.1751.1521.1641.059 6.250.6540.6640.6590.554 3.120.3830.3610.3720.267 1.560.2450.2320.2390.134 0.780.1760.1850.1810.076 00.1020.1080.105 |
本试剂盒所含材料:
A micro ELISA plate ---The 96-well plate has been pre-coated with an anti-human OPN antibody. This dismountable microplate can be divided into 12 x 8 strip plates.
Two vials lyophilized standard ---Dilute a bottle of the standard at dilution series, read the OD values, and then draw a standard curve.
One vial Biotin-labeled OPN antibody (100 x concentrate) (120 μl/bottle) ---Act as the detection antibody.
One vial HRP-avidin (100 x concentrate) (120 μl/bottle) ---Bind to the detection antibody and react with the TMB substrate to make the solution chromogenic.
One vial Biotin-antibody Diluent (15 ml/bottle) ---Dilute the Biotin-antibody.
One vial HRP-avidin Diluent (15 ml/bottle) ---Dilute the HRP-avidin solution.
本试剂盒不含材料:
A microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.
An incubator can provide stable incubation conditions up to 37°C±5°C.
Centrifuge
Vortex
Squirt bottle, manifold dispenser, or automated microplate washer
Absorbent paper for blotting the microtiter plate
货期:3-5 working days
×