首页 / 产品 / ELISA试剂盒 / 小鼠ELISA试剂盒
Intra-assay Precision (Precision within an assay): CV%<8% | ||||||
Three samples of known concentration were tested twenty times on one plate to assess. | ||||||
Inter-assay Precision (Precision between assays): CV%<10% | ||||||
Three samples of known concentration were tested in twenty assays to assess. |
To assess the linearity of the assay, samples were spiked with high concentrations of mouse ANG-1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. | ||||||
Sample | Serum(n=4) | |||||
1:1 | Average % | 89 | ||||
Range % | 85-96 | |||||
1:2 | Average % | 95 | ||||
Range % | 91-99 | |||||
1:4 | Average % | 94 | ||||
Range % | 90-98 | |||||
1:8 | Average % | 96 | ||||
Range % | 89-99 |
The recovery of mouse ANG-1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. | ||||||
Sample Type | Average % Recovery | Range | ||||
Serum (n=5) | 97 | 94-100 | ||||
EDTA plasma (n=4) | 93 | 89-106 |
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. | ||||||
ng/ml | OD1 | OD2 | Average | Corrected | ||
80 | 2.655 | 2.756 | 2.706 | 2.553 | ||
40 | 2.087 | 2.188 | 2.138 | 1.985 | ||
20 | 1.414 | 1.435 | 1.425 | 1.272 | ||
10 | 0.840 | 0.851 | 0.846 | 0.693 | ||
5 | 0.515 | 0.506 | 0.511 | 0.358 | ||
2.5 | 0.348 | 0.337 | 0.343 | 0.190 | ||
1.25 | 0.266 | 0.260 | 0.263 | 0.110 | ||
0 | 0.153 | 0.152 | 0.153 |
×